上海11选5走势图

   
Henan Sanqiang Medical Equipment Liability Co.,Ltd
Current location:Home > Products > High Pressure Autoclave
High Pressure Autoclave

Pulse&Vacuum Type

Update time:2017-07-06

Specification

Model

SQ-Z12

SQ-Z60

Volume

100L

200L

Type

Vertical

Vertical

Heating method

Electric

Electric

Power

10.0KW

20.0KW

Power supply

AC380V,50Hz

AC380V,50Hz

Carton size

1150x770x1520mm

1190x810x1580mm

Chamber size

420×700mm

500×1000mm

Net weight

263kg

305kg

Temperature display

LCD

LCD

Designed pressure

0。29MPa

0。29MPa

Rated working pressure

0。21Mpa;

0.21Mpa

Designed temperature

121℃/134℃

121℃/134℃

Pulse times

0~99

0~99

Sterilize time

0~9999 seconds

0~9999 seconds

Drying time

0~9999 seconds

0~9999 seconds


【Chamber safety valve】open≧0。23Mpa,close≦0。21Mpa;

【Pulse amplitude value】positive value 0.065Mpa~0.09Mpa,negative value -0.06Mpa~-0.08Mpa

【Pressure controller set】up switch value 0.23Mpa, down switch value 0.21Mpa

【Generator water source】soften water or purify water, the water temperature ≤45℃,water pressure 0~0.05 Mpa

【Vacuum pump water source】running water(should not be too hard), water pressure 0.10Mpa~0.20Mpa

【Air output】more than 99% (pulse more than 3 times)

【Vacuum drying】avoid the sterilized item wet after sterilization. 

【Pulse exhaust】Positive pressure dynamic pulse exhaust, eliminate the chamber indoor cold air completely, to ensure that the steam saturation

【Procedures】Equipped with liquid, culture medium sterilize thermal insulation, culture medium dissolved insulation, glass, utensils, rubber, a variety of procedures to choose。


Microcomputer control technology

上海11选5走势图The sterilizer using intelligent control of the microprocessor, man-made interface, easy to operate, safe and reliable. The parameters and status of the process are displayed dynamically through the digital screen. Vacuum, water injection, heat up, sterilization, pressure relief, exhaust, dry, power off automatically; equipment abnormal work automatically detect and alarm; fault automatic diagnosis, over-temperature, over-pressure automatic protection to ensure the reliability of sterilization. After the sterilization is complete, the buzzer automatically prompts that the ED display is complete.

Locking device

Before the sterilization cycle is started, the interlock is unlocked when the door is closed, and the door can be closed and turned on repeatedly. Only the door closed in place, the sterilizer can start running, in the course of the sterilizer door should not open. After the start of the cycle operation, if the failure and fault indication, the sterilization room is not fully released, interlock device should be locked, the sterilizer door should not open.


【Pulsation mode】 Microcomputer control according to site conditions automatically select the number of pulse to ensure the coordination of temperature and pressure。

【Vacuum】 Three times pre-vacuum, to ensure heating more faster, sterilization more thoroughly。

【Safety valve】 When the sterilizer pressure reaches 240kPa ± 5kPa, the safety valve automatically open to relief the pressure.

【Overpressure protection procedure】 When the sterilization chamber pressure reaches 220 ± 5kPakPa, there is a tone and can automatically pressure relief.

【Air Leakage】 When the sterilizer is tested at each stage, the pressure rise rate should not be greater than 0.13kPa / min.

[Sterilization chamber dynamic pressure] The pressure change during any 2s interval during the sterilizer cycle should not exceed 1000 kPa / min.

[Vacuum pump] Using a bowl of oil-free vacuum pump, simple and convenient, fast vacuum rate, long service life。 To ensure that the vacuum can reach-80kpa;

【Pressure sensor】 Built-in pressure sensor automatically detects the pressure inside the chamber to ensure accurate and effective pressure inside the cavity.

【Temperature sensor】 Built-in temperature sensor automatically detects the temperature inside the cavity to ensure that the cavity to maintain the use of temperature within ± 3 ℃ within the precise range.

【Sterilization mode】 Were bare equipment, cotton yarn, parcel, plastic and rubber products, the default operating temperature of 135 ℃.

【Automatic drying】 Strong vacuum drying, for different items dry demand; equipment residual humidity<0.2%.

【Steam inside the row】 Built-in condensate collector, waste steam will be exclusion after condensed by the condenser, not outside the row of waste steam, more safe and clean。

【Seal structure】 Seal ring for the silicone products, design life of 2 years (1200 times) is not aging is not deformed.

【Casters】 Yes

【Alarm system】 Has a high and low temperature alarm system

【Category】 Class B medical equipment


Click refresh

Related products

Related news

Products

Contact

Sales Tel:  +86-400-672-7500

Foreign trade Tel:+86-372-5577488

Shanghai office:+86-21-68751982

Company Tel:+86-372-5577388

                       +86-372-5577588

After sale:+86-372-5577599


Contact us

WeChat subscription

WeChat service

Mobile terminal

Sales Tel: +86-400-672-7500

Foreign trade Tel: +86-372-5577488

Shanghai office: +86-21-68751982

上海11选5走势图After sale: +86-372-5577599

Company Tel: +86-372-5577388

Company Tel: +86-372-5577588


Copyright © Henan Sanqiang Medical Equipment Liability Co.,Ltd  http://en.plhykc.com/Disclaimer  
上海11选5 上海11选5 上海11选5分布走势图 上海11选5开奖结果 易玩棋牌 悠洋棋牌下载 上海11选5APP 福运彩票平台 上海11选5 上海11选5走势图